Most rocker switch enquiries start with the same question: “Do you have a 20A switch?”
Amperage is the easiest parameter to compare and the least useful on its own. Two switches can carry identical ratings and behave completely differently in the panel, because the parameter that actually determines whether a circuit works is the contact configuration — how many independent circuits the switch controls, and how many positions each circuit can be thrown into.
Get the configuration wrong and the failure is not subtle. A single-pole switch cannot isolate a positive and negative together. A maintained switch cannot return a winch to rest by itself. A double-pole changeover cannot feed two separate loads from one source.
This guide explains the configuration system used across standard marine and automotive rocker switches, how to read the function code, and how pin assignments map to each type.
Why Does Configuration Matter More Than Current Rating?
A 20A rating tells you the switch will survive a 20A resistive load. It tells you nothing about:
- whether the circuit can be isolated on both conductors
- whether the actuator latches or springs back
- how many independent loads one switch can control
- which terminal receives power and which delivers it
In marine and RV systems these questions decide whether the switch is legal, safe, and usable. ABYC-compliant battery isolation, for example, generally requires breaking both positive and negative — a single-pole switch physically cannot do that regardless of its amperage.
Configuration is the first decision. Rating is the second.
What Do Poles and Throws Actually Mean?
Standard switch nomenclature is a two-part name, and each part answers a separate question.
Poles = how many independent circuits the switch can switch at the same time.
- SP (Single Pole) — one circuit
- DP (Double Pole) — two independent circuits, operated together
Throws = how many positions each pole can connect to.
- ST (Single Throw) — connects or disconnects. Two positions: ON and OFF
- DT (Double Throw) — can route to either of two outputs. Three positions in practice: A, OFF, B
Combining them gives the familiar types:
| Type | Circuits | Positions per circuit | Typical use |
|---|---|---|---|
| SPST | 1 | ON–OFF | Single light, single pump |
| SPDT | 1 | A–OFF–B | Two lights from one switch, or changeover |
| DPST | 2 | ON–OFF | Isolating positive and negative together |
| DPDT | 2 | A–OFF–B | Two loads on one switch, or polarity reversal |
| DPTT | 2 | three active positions | Three-state dual circuit |
One clarification that causes a lot of specification errors: DPDT is not “double pole double throw” in the sense of four outputs. It is two poles, each individually capable of two throws. The two poles move together but can be wired to unrelated circuits — which is exactly why DPDT is the standard choice for reversing a DC motor.
What Are the 11 Standard Rocker Switch Functions?
Rocker switches are commonly built to a small set of standard functions, identified by letter. The same letter is used in both the single-pole and dual-pole families, which is convenient once you know the system — but the electrical type it produces is different.
Single Pole
| Code | Function | Type | Pins used |
|---|---|---|---|
| A | ON–OFF | SPST | 2 |
| B | (ON)–OFF | SPST | 2 |
| C | ON–ON | SPDT | 3 |
| D | (ON)–ON | SPDT | 3 |
| E | ON–OFF–ON | SPDT | 3 |
| F | (ON)–OFF–ON | SPDT | 3 |
| G | (ON)–OFF–(ON) | SPDT | 3 |
Dual Pole
| Code | Function | Type | Pins used |
|---|---|---|---|
| A | ON–OFF | DPST | 4 |
| B | (ON)–OFF | DPST | 4 |
| C | ON–ON | DPDT | 6 |
| D | (ON)–ON | DPDT | 6 |
| E | ON–OFF–ON | DPDT | 6 |
| F | (ON)–OFF–ON | DPDT | 6 |
| G | (ON)–OFF–(ON) | DPDT | 6 |
| H | ON–ON–ON | DPTT | 6 |
| I | ON–ON–OFF | DPDT | 6 |
| J | (ON)–ON–OFF | DPDT | 6 |
| K | (ON)–ON–ON | DPTT | 6 |
Note that H and K are DPTT — dual pole, three active positions. These are the least understood entries in the table and the ones most often mis-specified. A DPTT switch has three positions and no OFF position at all; power is always flowing to one of three outputs. If a circuit needs a definite off state, H and K are the wrong choice.
What (ON) Actually Means: Momentary vs Maintained
The parentheses are the single most overlooked notation in switch specification.
- ON (no brackets) = maintained. The switch latches in that position. Release the actuator and it stays there.
- (ON) (in brackets) = momentary. The switch is spring-return. It is only in that position while held.
This distinction changes the application entirely:
- A maintained ON–OFF switch is correct for a cabin light — you want it to stay on.
- A momentary (ON)–OFF switch is correct for a horn — you want it to stop when you let go.
- A centre-off momentary (ON)–OFF–(ON) switch is the correct type for a winch in/out control, because both directions retract on release. A maintained version of the same switch would keep the winch running after the operator let go.
Standard practice on winch and trim-tab controls is explicitly momentary in both directions, for this reason. When specifying, the notation is the specification — writing it as “ON-OFF-ON” instead of “(ON)-OFF-(ON)” produces a completely different and potentially unsafe part.
Pin Assignments: Which Pin Is Power In?
The function code determines not just how many pins are used, but which pin does what. For single-pole switches:
| Code | Pin 1 | Pin 2 | Pin 3 |
|---|---|---|---|
| A / B | — | Power in | Power out |
| C / D / E / F / G | Power out | Power in | Power out |
For dual-pole switches, pins 5 and 6 mirror pins 2 and 3:
| Code | Pin 1 | Pin 2 | Pin 3 | Pin 4 | Pin 5 | Pin 6 |
|---|---|---|---|---|---|---|
| A / B | — | in | out | — | in | out |
| C / D / E / F / G / H / I / J / K | out | in | out | out | in | out |
Two practical consequences follow.
First, pin 2 is always the power input on both families. That is the anchor for wiring and it makes harness design predictable across different function codes.
Second, the pin count is driven by required circuits, not by the switch body. Single-pole A uses 2 pins; single-pole C–G use 3. Dual-pole A uses 4; dual-pole C–K use 6. A 6-pin switch body can carry a 4-pin function — the unused positions stay empty. This is why ordering by pin count alone is unreliable; the function code is the real identifier.
How Do You Read a Rocker Switch Part Number?
A configurable rocker switch is not a single part number but a small specification built from encoded fields. The standard encoding uses seven fields:
| Field | Meaning | Options |
|---|---|---|
| 1 | Prefix | A |
| 2 | Base | 1 → 8 pins · 2 → 6 pins · 3 → 8 pins with barriers · 4 → 10 pins |
| 3 | Poles | 1 → single pole · 2 → double pole |
| 4 | Cover / actuator | 1 → 9 plus K J E F G L L1 M N O P X Y Z |
| 5 | Light | 0 → unlit · 1 → single lamp · 2 → dual lamp |
| 6 | Electrical function | A through K |
| 7 | Lens colour | B black · R red · G green · BL blue · O orange · W white |
Reading left to right, a part number tells you the physical base, the electrical behaviour, the illumination, and the appearance — in that order of engineering significance.
Three details in this system are worth flagging for anyone specifying a custom panel:
Actuator choice is a styling and legibility decision, not a cosmetic one. Actuator styles L, J, X and E are laser-engravable, which means the symbol is cut into the material rather than printed on it. On a deck-mounted panel exposed to UV, salt, and cleaning chemicals, engraved symbols survive where printed ones abrade away.
Lighting count must match the function. Field 5 offers unlit, single-lamp, and dual-lamp. A dual-lamp actuator is normally used to show two states independently — for example, an illuminated legend that stays visible with the circuit off, plus a second lamp indicating the circuit is on. Mounting a two-lamp actuator on a single-lamp circuit leaves one lamp doing nothing.
Base type constrains pin count before function is chosen. A 6-pin base (type 2) cannot carry a function that needs 8 pins. If a future configurator upgrade requires additional circuits, the base has to be specified accordingly from the start.
Symbols are selected separately from the part number. The standard library includes over a hundred laser-etched industrial and marine symbols plus printing-based symbol sets, and custom symbols can be engraved to order. For OEM programmes this is usually where branding differentiation is actually delivered.
The question that follows from configuration is almost never about the switch, it is about the harness. Once you know a function needs six pins in a dual-pole base, the next decision is what lands on those pins — ring terminals, plug connectors, or a pre-terminated harness — and that choice is what determines whether the panel survives vibration. Configurations are standardised; terminations are not.
Which Configuration Suits Your Load?
Configuration choices map fairly cleanly onto application categories:
Single-pole switch, single load. Cabin lights, deck lights, bilge pump control, ventilation fans, USB outlets. SPST A/B is sufficient and cheapest.
Single-pole changeover. Two loads alternate from one switch position — navigation versus anchor light, or one of two pump sources. SPDT E (ON–OFF–ON) is the standard answer.
Dual-pole for isolation. Any circuit where the negative conductor must also break, or where two circuits must be isolated together. DPST A/B. This is the correct choice for battery isolation switching, not a high-amperage SPST.
Dual-pole changeover for polarity reversal. DPDT is the conventional configuration for reversing DC motors and for battery bank selection between two sources. DPDT C–G.
Dual-pole momentary for motion control. Winches, trim tabs, and powered hatches. DPDT G, the (ON)–OFF–(ON) version.
Dual-pole three-position for multi-state selection. Three-source battery selection, multi-tank level reporting. DPTT H and K.
A separate caution applies to all of them. Configuration determines how the circuit is switched; it does not determine what the switch can survive. Motors, pumps, and other inductive loads draw inrush current several times their running current, and DC arcs do not self-extinguish the way AC arcs do at zero crossing. Where a load is inductive and significant, the switch’s job is normally to energise a relay rather than to carry the motor current directly. Sizing a switch by running current alone is the most common cause of premature contact failure — regardless of configuration.
Specification Reference
Standard electrical and mechanical characteristics for this switch family:
| Parameter | Specification |
|---|---|
| Rating | 12V 20A / 24V 10A DC · 125V 15A / 250V 10A AC |
| Dielectric strength | 1,500 V RMS |
| Insulation resistance | 50 MΩ |
| Electrical life | 10,000 cycles per circuit |
| Mechanical endurance | 50,000 cycles minimum |
| Operating temperature | −40 °C to +85 °C |
| Contact material | Silver tin oxide (AgSnO₂) |
| Terminals | Silver-plated copper, 1/4″ (6.3 mm) |
| Housing | Flame-retardant PBT/PC alloy base · PC frame · PC inner cover, ABS outer cover |
| Lamp life | Incandescent 10,000 h · Neon 25,000 h · LED 50,000 h |
| Ingress protection | IP66 standard · IP67 available to order |
| Certification | UL, CE, RoHS |
| Panel cut-out | 21.2 × 37.2 mm |
Available accessories include mounting panels (single, middle, end, and six-position), hole plugs, 8-pin and 10-pin connectors, pre-printed label sets for boat and automotive use, actuator removal tools, and terminal plug springs.
FAQ
What is the difference between SPST and SPDT? SPST switches one circuit into on or off. SPDT switches one circuit between two outputs, with a centre off position. SPDT can do everything SPST does plus changeover, at the cost of one extra terminal.
Can I use a single-pole switch to isolate a battery? Generally no. Battery isolation normally requires breaking both conductors, which needs at least dual pole. Amperage rating does not substitute for pole count.
What does the bracket mean in (ON)-OFF? Brackets indicate a momentary position. The switch is only in that state while the actuator is held and springs back when released. Unbracketed ON is maintained and latches.
How do I know which pin is power in? On this switch family, pin 2 is the power input on both single-pole and dual-pole versions. Pins 3 and 6 are power out; pins 1 and 4 are the second output on three-position functions.
Is a 20A switch suitable for a motor or pump? Only if the load is genuinely within rating including inrush. Motor and pump startup current commonly runs several times the running current, so a relay is the usual arrangement. Select contact configuration first, then confirm the inductive load is handled.
Can symbols be customised? Yes. The standard library covers laser-etched and printed symbols, and custom engraving is available for OEM programmes, typically on the laser-engravable actuator styles.
Which actuator types can be laser engraved? Styles L, J, X and E are laser-engravable.
What is the difference between DPDT and DPTT? DPDT is dual pole, two throws per pole, with a centre off. DPTT is dual pole with three active positions and no off position — power always flows to one of three outputs.
—